Aim:To establish the pharmacokinetic (PK) and pharmacodynamic (PD) equivalence of proposed biosimilar Insulin N (Biocon's Insulin‐N; Biocon Biologics Ltd., Bangalore, India) and US‐licensed Humulin® N (Humulin‐N; Eli Lilly and Company, Indianapolis, IN, USA) in healthy subjects.
Materials and Methods:This was a phase‐1, single‐centre, double‐blind, randomized, three‐period, six‐sequence, partially replicated, crossover, 24‐h euglycaemic clamp study. Overall, 90 healthy subjects were randomized, of whom 85 completed the study. The subjects received either two single doses of Biocon's Insulin‐N and a single dose of Humulin‐N or two single doses of Humulin‐N and a single dose of Biocon's Insulin‐N subcutaneously at a dose of 0.4 IU/kg. The primary PK endpoints were the area under the insulin concentration‐time curve from 0 to 24 h (AUCins.0‐24h) and the maximum insulin concentration (Cins.max). The primary PD endpoints were the area under the glucose infusion rate (GIR) curve from 0 to 24 h (AUCGIR.0‐24h) and the maximum GIR (GIRmax).
Results:Biocon's Insulin‐N was found to be equivalent to Humulin‐N for the primary PK (geometric 90% confidence interval for the least squares mean ratio: AUCins.0‐24h, 100.98%‐115.66% and Cins.max, 95.91%‐110.16%) and PD endpoints (intra‐subject variability ≥0.294; 95% upper confidence interval [(μT – μR)2 − θσ2WR] <0; point estimates of geometric least squares mean ratio: AUCGIR.0‐24h, 104.61% and GIRmax, 100.81%). The safety profile of Biocon's Insulin‐N was similar to that of Humulin‐N, and no serious adverse events were reported.
Conclusion:PK and PD equivalence was shown between Biocon's Insulin‐N and Humulin‐N in healthy subjects, and both treatments were well tolerated and considered safe.